BaselineStarting out with the standard Bika multi sample COA, clients have sponsored the coding of improved versions less generic and agreed for them to be included in public releases and will be available for selection with bika.coa installed The all deviate, in one way or another, in the way the results are presents from the standard, bika.coa:Multi.pt, a flat 2D layout - Samples per Column, Analyses per row A Sample header block, consisting of the attributes Sample and Client Sample ID, Sample Type, Sample Point Dates Sampled, Received and Verified The Analysis rows have cells for Method, Verifier, Unit and Result ImexMultiAdds Specification min and max columns as well as LDL. It therefor requires the same Specification for all the Samples and the COA will render a warning if not. Sponsored by Imex
|
Multi Sample COAs per BatchSome labs prefer to publish their COAs per Batch and include Batch information in the header, e.g. Batch remarks, and also the information shared by the Samples, e.g. they are always Received together, and/or of the same Sample Type, or Verified by the same person GeongolBatchMultiThis COA features a summary of the Analysis Services on the COA an the Instruments used in their analysis Sponsored by Geoangol for use in Bika Fire Assay GreenhillMultiThis COA adds the Batch remarks to the report and uses the Client Batch ID as client order number. Sample Condition is added per Sample Sponsored by Greenhill for use in Bika Dairy AWTCBatchMultiThis template was coded for inhouse water treatment analysis and does not include Verifier and Method columns Analyses are listed strictly by Sort Order and included whether they were requested or not The Batch Titled is used as the Project Title Sponsored by AWTC Water Treatement Consultancy for use in Bika Water HydrochemLocationMultiReports results for all the Sample Points at a specific Location. By HydroChem Water Specialists It features Specification ranges per Sample as they are often of different Sample Types
|
ZimlabsTransposedMultiThis COA transposes the results table an put Samples on rows and the Analyses in columns. It is suitable for big batches of results where all the samples had only two or three tests done on them as is often the case with Geo chemistry LIMS at mines Sponsored by Zimlabs for use in Bika Fire Assay The COA also use date ranges, from start to finish for the Samples' dates analysed and Verified
A summary of all the Methods used for the Analyses of the Samples - all the same, is included All the QC results associated with the routine results are also listed The results are presented by Client Sample IDs per row, Analyses in columns The COA also carries a watermark |